若您需要咨询产品或有任何技术问题,请通过官方电话 400 885 9050 或邮箱 info.cn@stemcell.com 与我们联系。

EasySep™人NK细胞富集试剂盒

免疫磁珠负选未标记的人NK细胞
只有 %1
¥11,154.00

产品号 #(选择产品)

产品号 #19055_C

免疫磁珠负选未标记的人NK细胞

产品优势

  • 操作简单、快捷,且无需分离柱
  • 纯度高达95%
  • 获得的活细胞无标记

产品组分包括

  • EasySep™ 人NK 细胞富集试剂盒(产品号 #19055)
    • EasySep™人NK细胞富集抗体混合物, 1 mL
    • EasySep™ D Magnetic Particles磁珠, 2 x 1 mL
  • RoboSep™ 人NK细胞富集试剂盒(含过滤吸头)(产品号 #19055RF)
    • EasySep™人NK细胞富集抗体混合物, 1 mL
    • EasySep™ D Magnetic Particles磁珠, 2 x 1 mL
    • RoboSep™ 缓冲液(产品号 #20104)
    • RoboSep™过滤吸头(产品号 #20125)
New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more
专为您的实验方案打造的产品
要查看实验方案所需的所有配套产品,请参阅《实验方案与技术文档》

总览

通过免疫磁珠负选,从新鲜或冻存的人外周血单个核细胞 (PBMCs) 或裂解的白细胞单采术样本中分离出无磁珠标记和高纯度的NK细胞。EasySep™技术结合单克隆抗体的特异性和无柱磁分选系统的简便性,已在发表的研究中广泛应用超过20年。

在该EasySep™负选流程中,非目的细胞被抗体复合物与磁珠标记。以下非目标细胞将被特异性去除:粒细胞、T细胞、B细胞、单核细胞、树突状细胞及红系细胞。通过EasySep™磁极将被磁珠标记的细胞与未被标记的目的人NK细胞分离,接着简单地将目的细胞倾倒或吸取至一个新的试管中。完成磁珠细胞分选后,目的NK细胞即可用于流式细胞术、培养或DNA/RNA提取等下游应用。

如需更快速的细胞分选,我们推荐使用EasySep™ 人NK细胞分选试剂盒(产品号 #17955),仅需8分钟即可完成细胞分选。

了解更多关于免疫磁珠EasySep™技术的工作原理,或如何通过RoboSep™实现免疫磁珠细胞分选全自动化。或选择即用型、符合伦理来源的用EasySep™ 人NK细胞富集试剂盒进行分选的冻存原代人外周血NK细胞。探索为您的实验流程优化的更多产品,包括培养基、补充剂、抗体等。

磁极兼容性
• EasySep™磁极(产品号 #18000)
• “The Big Easy” EasySep™磁极(产品号 #18001)
• Easy 50 EasySep™磁极(产品号 #18002)
• EasyPlate™ EasySep™磁极(产品号 #18102)
• EasyEights™ EasySep™磁极(产品号 #18103)
• RoboSep™-S(产品号 #21000)
 
分类
细胞分选试剂盒
 
细胞类型
NK 细胞
 
种属

 
样本来源
PBMC
 
分选方法
负选
 
应用
细胞分选
 
品牌
EasySep,RoboSep
 
研究领域
免疫
 

实验数据

FACS Profile Results With EasySep™ Human NK Cell Enrichment Kit

Figure 1. FACS Profile Results With EasySep™ Human NK Cell Enrichment Kit

The NK cell content of the enriched fraction varies, depending on the starting sample. Starting with previously frozen mononuclear cells containing more than 10% NK cells, the NK cell content of the enriched fraction typically ranges from 73% - 95%. Purities may be lower when starting with samples containing less than 10% NK cells.

产品说明书及文档

请在《产品说明书》中查找相关支持信息和使用说明,或浏览下方更多实验方案。

Document Type
Product Name
Catalog #
Lot #
Language
Catalog #
19055RF
Lot #
All
Language
English
Catalog #
19055
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19055RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19055RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 3
Catalog #
19055RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19055
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19055
Lot #
All
Language
English

应用领域

本产品专为以下研究领域设计,适用于工作流程中的高亮阶段。探索这些工作流程,了解更多我们为各研究领域提供的其他配套产品。

相关材料与文献

技术资料 (11)

常见问题 (11)

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.

文献 (57)

Dysregulated inflammation in solid tumor malignancy patients shapes polyfunctional antibody responses to COVID-19 vaccination R. A. Purcell et al. NPJ Vaccines 2025 Oct

Abstract

Solid tumor malignancy (STM) patients experience increased risk of breakthrough SARS-CoV-2 infection owing to reduced COVID-19 vaccine immunogenicity. However, the underlying immunological causes of impaired neutralization remain poorly characterized. Furthermore, non-neutralizing antibody functions can contribute to reduced disease severity but remain understudied within high-risk populations. We dissected polyfunctional antibody responses in STM patients and age-matched controls who received adenoviral vector- or mRNA-based COVID-19 vaccine regimens. Elevated inflammatory biomarkers, including agalactosylated IgG, interleukin (IL)-6, IL-18, and an expanded population of CD11c−CD21− double negative 3 (DN3) B cells were observed in STM patients and were associated with impaired neutralization. In contrast, mRNA vaccination induced Fc effector functions that were comparable in patients and controls and were cross-reactive against SARS-CoV-2 variants. These data highlight the resilience of Fc functional antibodies and identify systemic inflammatory biomarkers that may underpin impaired neutralizing antibody responses, suggesting potential avenues for immunomodulation via rational vaccine design.
Osteoclast-expanded supercharged NK cells perform superior antitumour effector functions BMJ Oncology 2025 Jun

Abstract

AbstractObjectiveNatural killer (NK) cells are the largest innate lymphocyte subset with potent antitumour and antiviral functions. However, clinical utilisation of human NK cells is hampered due to a lack of reliable methods to augment their antitumour potential. We demonstrated technology in which human NK cells were cocultured with osteoclasts in the presence of probiotic bacteria. This approach significantly augmented the antitumour cytotoxicity and polyfunctionality of human NK cells, resulting in the generation of supercharged NK (sNK) cells.Methods and analysisWe explored the proteomic, transcriptomic and functional characterisation of sNK cells using cell imaging, flow cytometric analysis, 51-chromium release cytotoxicity assay, ELISA, ELIspot, IsoPLexis single-cell secretome analysis, proteomic analysis, RNA analysis, western blot and enzyme kinetics.ResultsWe found that sNK cells were less susceptible to split anergy and tumour-induced exhaustion. Proteomic analyses revealed that sNK cells significantly increased their cell motility and proliferation. Single-cell transcriptomes uncovered sNK cells undertaking a unique differentiation trajectory and turning on STAT1, JUN, BHLHE40, ELF1, MAX and MYC regulons essential for augmenting antitumour effector functions and proliferation, respectively. Both proteomic and single-cell transcriptomes revealed that an increase in Cathepsin C helped to augment the quantity and function of Granzyme B.ConclusionsThese results support that this unique method produces potent NK cells for clinical utilisation and delineate the molecular mechanisms associated with this process.
Modeling mesenchymal stromal cell support to hematopoiesis within a novel 3D artificial marrow organoid system Scientific Reports 2025 Jul

Abstract

The human bone marrow (BM) microenvironment involves hematopoietic and non-hematopoietic cell subsets organized in a complex architecture. Tremendous efforts have been made to model it in order to analyze normal or pathological hematopoiesis and its stromal counterpart. Herein, we report an original, fully-human in vitro 3D model of the BM microenvironment dedicated to study interactions taking place between mesenchymal stromal cells (MSC) and hematopoietic stem and progenitor cells (HSPC) during the hematopoietic differentiation. This fully-human Artificial Marrow Organoid (AMO) model is highly efficient to recapitulate MSC support to myeloid differentiation and NK cell development from the immature CD34 + HSPCs to the most terminally differentiated CD15 + polymorphonuclear neutrophils, CD64 + monocytes or NKG2A-KIR2D + CD57 + NK subset. Lastly, our model is suitable for evaluating anti-leukemic NK cell function in presence of therapeutic agents. Overall, the AMO is a versatile, low cost and simple model able to recapitulate normal hematopoiesis and allowing more physiological drug testing by taking into account both immune and non-immune BM microenvironment interactions.Supplementary InformationThe online version contains supplementary material available at 10.1038/s41598-025-07717-9.

更多信息

更多信息
物种 人类
Magnet Compatibility • EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • Easy 50 EasySep™ Magnet (Catalog #18002) • EasyPlate™ EasySep™ Magnet (Catalog 18102) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
样本来源 PBMC
Selection Method Negative
标记抗体
质量保证:

产品仅供研究使用,不用于针对人或动物的诊断或治疗。 欲获悉更多关于STEMCELL的质控信息,请访问 STEMCELL.CN/COMPLIANCE.
Copyright © 2025 by STEMCELL Technologies. All rights reserved.

在线联系